Silicon Labs /EFR32ZG23B011F512IM40 /PROTIMER_S /RXCTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as RXCTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLED)RXSETEVENT1 0RXSETEVENT2 0RXCLREVENT1 0RXCLREVENT2

RXSETEVENT1=DISABLED

Description

No Description

Fields

RXSETEVENT1

First event that sets RX req signal

0 (DISABLED): Request is never set

1 (ALWAYS): Does not wait for any particular event

2 (PRECNTOF): Pre counter overflow

3 (BASECNTOF): Base counter overflow

4 (WRAPCNTOF): Wrap counter overflow

5 (TOUT0UF): Timeout counter 0 underflow

6 (TOUT1UF): Timeout counter 1 underflow

7 (TOUT0MATCH): Timeout counter 0 match

8 (TOUT1MATCH): Timeout counter 1 match

9 (CC0): Channel 0 Capture/Compare event

10 (CC1): Channel 1 Capture/Compare event

11 (CC2): Channel 2 Capture/Compare event

12 (CC3): Channel 3 Capture/Compare event

13 (CC4): Channel 4 Capture/Compare event

14 (TXDONE): MOD indicated that TX completed

15 (RXDONE): FRC indicated that RX completed

16 (TXORRXDONE): MOD/FRC indicated that TX or RX completed

17 (FDET0): DEMOD indicated that syncword 0 was detected

18 (FDET1): DEMOD indicated that syncword 1 was detected

19 (FDET0OR1): DEMOD indicated that syncword 0 or 1 was detected

20 (LBTSUCCESS): LBT completed successfully

21 (LBTRETRY): LBT detected occupied channel and will try again

22 (LBTFAILURE): LBT could not start transmission

23 (ANYLBT): Any LBT event

24 (CCAACK): A CCA measurement completed

25 (CCA): A CCA measurement completed, and channel was clear

26 (NOTCCA): A CCA measurement completed, and channel was busy

27 (TOUT0MATCHLBT): Timeout counter 0 match occurred during LBT operation

RXSETEVENT2

Second event that sets RX req signal

RXCLREVENT1

First event that clears RX req signal

RXCLREVENT2

Second event that clears RX req signal

Links

()